Pneumatic cut off the valve valve closed dead processing
The author: Time:2019/9/4

气动切断阀阀门关不死的处理
1.行程调整不当
    因为氧气切断阀属于常闭型阀门,即在失电、失气的情况下会自动关闭(关闭力来自弹簧),如果关不死,可能是行程调整不当造成,即弹簧的弹力全部释放后,阀芯与阀座之间仍有间隙。处理方法是松开推拉杆与阀杆连接处的并帽与定位螺钉,用管钳或活动扳手夹住阀杆逆时针方向旋转使阀芯向上运动直到关闭。
  2.手动机构未关到位或手动机构锁紧螺栓未锁
    手动机构采用的是蜗轮蜗杆,具有自锁作用,如果进行手动操作后未将阀芯完全关闭,或者由于手动机构锁紧螺栓未锁造成误操作,则气动时阀的行程受限永远无法关闭。

 

On an article:Daily maintenance of pneumatic control valve       Next article:Regulating valves are standardized in the following areas
 